SEAM-LOC 24

®

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11

800.406.7387 (Corporate Office) • www.metalsales.us.com

Ul f

ire

r

esisTanCe

r

aTings

METAL SALES MANUFACTURING CORPORATION

R9697

Mechanically attached metal roof panels - Type “Seam-Loc 24” secured by steel anchor clips.

Anchor clips are attached to a hat shaped member* (minimum depth 1 in.) or a bearing plate**.

For use in Design Nos. P224 , P225 , P227 , P230 , P237 , P508 , P510 , P512 , P701 , P711 , P712

, P713 , P715 , P717 , P720 , P722 , P723 , P724 , P726 , P731 , P734 , P736 , P803 , P814 , P815 ,

P818 , P819 , P821 , P823 , P824 .

*Hat shaped member to be a minimum of 16 gauge. The member will be fastened through the roof

insulation to the steel roof deck with min. No. 14 self-drilling and/or self-tapping fasteners. Spacing

to be determined by the structural loading requirements. In addition any compressible UL Classified

glass fiber blanket insulation with or without a vapor retarder facing may be used between the speci-

fied roof insulation and the metal roof panels.

**Bearing plate to be a minimum of 16 gauge. Member will be fastened through the roof insulation to

the steel deck with min. No. 14 self-drilling and/or self-tapping fasteners.

See the UL Fire Resistance Directory for explanation of each design number listed above.

Metal Roof Deck Panels

Metal Sales Manufacturing Corporation has obtained fire resistance ratings for various products

conducted according to test criteria set forth by 'Underwriters Laboratories' "Standard Fire Tests

of Building Construction and Material" (ANSI/UL 263). This test procedure is identical to ASTM

E-119 and NFPA 251.

The fire resistance rating is for the total assembly and not just the external metal panel. Ratings

are expressed in hours and vary depending upon the assemblies. In general, the test criteria is to

evaluate the assembly's ability to continue to support the superimposed loads and resist the pas-

sage of flame, high temperatures, or hot gases which will ignite combustible materials. The test

assemblies are identified by an alpha-numeric design number.

For detail information on specific assemblies and hourly ratings see UL Fire Resistance Directory.

Underwriters Laboratories Inc.

®

UL

®

LISTED