PSL-4
SEAM-LOC 24
®
© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11
800.406.7387 (Corporate Office) • www.metalsales.us.com
SSR RAKEWALL
COUNTER FLASHING
REGLET FLASHING
SSR RIDGE
VENTED RIDGE COVER
VENT DRIP
SSR HIGH SIDE
Length 10'-2"
Length 10'-2", 20'-3" - *Specify Slope Angle
1"
C
3
/
4
"
3
/
4
"
5
/
8
"
Length 10'-2"
1
/
2
"
C
1"
2"
Hem
Length 10'-2"
3
1
/
4
"
3
/
4
"
120°
C
1"
4"
4"
X*
C
Length 10'-2", 20'-3" - *Specify Slope Angle
EXPANSION JOINT
Length 10'-2", 20'-3" - *Specify Slope Angle
C
4"
4"
4"
1"
X*
PITCH BREAK
6"
Hem
C
4"
135°
Hem
Hem
3"
3"
1
1
/
8
"
7
/
8
"
X*
1"
SSR SCULPTURED
FLASHING
4"
C
Hem
1"
45°
Length 10'-2", 20'-3" - *Specify Slope Angle
4"
4"
X*
C
160°
Hem
5
/
8
"
6
1
/
2
"
100°
2"
2"
Length 10'-2"
Length 10'-2"
HIGH SIDE EAVE
C
SSR SCULPTURED
SSR SCULPTURED
PEAK BOX
CORNER BOX
C
C
SSR GUTTER SUPPORT
1"
7
/
8
"
C
3
/
4
"
3
/
8
"
f
lashing
P
rofiles
(
ConT
.)
C- Indicates color side of flashing.
SEAM-LOC 24
Z-CLOSURE
1
3
/
8
"
2
5
/
8
"
1
3
/
8
"
Length 10'-2"
Length 0'-10"
C
60°
1
1
/
4
"