beautypg.com

Seam-loc 24 – Metal Sales Seam-Loc 24 Manual User Manual

Page 10

background image

PSL-10

SEAM-LOC 24

®

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11

800.406.7387 (Corporate Office) • www.metalsales.us.com

s

eCTion

P

roPerTies

and

g

eneral

i

nformaTion

ALLOWABLE UNIFORM LIVE LOADS PSF

(3 or More Equal Spans)

2' 3' 3.5' 4' 4.5' 5' 2' 3' 3.5' 4' 4.5' 5'

SECTION PROPERTIES

Bottom in Compression

Width

(in.)

Yield

KSI

24"

50

24

Ga.

Sxx

In

3

/ft

Ixx

In

4

/ft

Weight

PSF

1.09

Top in Compression

Sxx

In

3

/ft

Ixx

In

4

/ft

0.2055

0.0952 0.0920

0.0653 342

161

120 93 74 60 70 59 54 49 43 38

0.2055

0.0952

0.0920

0.0653 342 161 120 93 74 60 131 105 92 79 66 54

0.2480

0.1221

0.1220

0.0869 455 214 160 123 98 80 93 78 70 62 54 46

0.2480

0.1221

0.1220

0.0869 455 214 160 123 98 80 169 134 117 100 83 66

0.2725

0.1263

0.1280

0.0882 458 217 161 125 99 81 74 64 59 54 49 44

Inward (Gravity / Deflection)

Load

Outward Uplift (Stress)

Load

24"

50

24*

1.09

1. Theoretical section properties have been calculated per AISI 2007 “Specification for the Design of Cold-formed Steel Structural Members.” Ixx and Sxx are

effective section properties for deflection and bending.

2. Allowable load is calculated in accordance with AISI 2007 specifications considering bending, shear, combined bending and shear, deflection, and

ASTM E-1592 testing and fastener pullout from 16 ga. supports. Allowable load considers the worst case of 3 and 4 equal span conditions. Allowable load

does not address web crippling. Panel weight is not considered.

3. Deflection consideration is limited by a maximum deflection ratio of L/180 of span.

4. Allowable loads do not include a 1/3 stress increase in uplift.
* Loads determined using the S-5! Clamp at each panel clip.

18"

50

24

1.15

18"

50

24*

1.15

22

24"

50

1.43

Slope

Substructure

Clips

Coverage

Length

Fasteners

Availability

GENERAL INFORMATION

ATTACHMENT DETAILS

PANEL CLIP

The minimum recommended slope for the Seam-Loc 24

®

roof panel is 1/4:12.

Seam-Loc 24

®

is designed to be utilized over open

structural framing or a solid substrate.

Clip spacing is based upon the spacing of structural framing

members and loading requirements.

Seam-Loc 24

®

panels are available in a 2

11

/

16

" seam height

with a 24" or 18" width coverage.

Minimum factory cut length is 5'-0". Maximum

recommended panel length is 45'-0". Longer panels

require additional consideration in packaging, shipping, and

erection. Please consult Metal Sales for recommendations.

The fastener selection guide should be consulted for

choosing the proper fastener for specific applications.

Quantity and type of fastener must meet necessary loading

and code requirements.

NOTE: All panels are subject to surface distortion due to

improperly applied fasteners. Overdriven fasteners will

cause stress and induce oil canning across the face of the

panel at or near the point of attachment.

Finishes: Acrylic Coated Galvalume

®

and

PVDF (Kynar 500).

Gauges: 24ga and 22ga

Clip

Seam-Loc 24

®

Panel

Factory Applied Sealant

BEFORE SEAMING

AFTER SEAMING

Clip Fastener

Clip

Seam-Loc 24

®

Panel

Factory Applied Sealant

Clip Fastener

S-5! Clamp (Optional)

Factory Applied Sealant

24" Coverage

C

18

1

/

2

"

2

5

/

8

"

2

11

/

16

"