Configuration
7-6
UOOu_^MTMO
L
Code
IMPORTANT
Possible settings
Name
Code
IMPORTANT
Info
Selection
Lenze
Name
C119
¿ Function PTC
822X/824X
-0-
-0-
PTC input inactive
-1-
PTC input active,
TRIP and IMP (pulse inhibit) are set
-2-
PTC input active, warning
C120 I
2
¡ t switch off
822X/824X
0
0
{1 %}
100
C125
¿* LECOM baud rate
-0-
-0-
9600 baud
-1-
4800 baud
-2-
2400 baud
-3-
1200 baud
-4-
19200 baud
Only for LECOM
applications
C142
¿ Start condition
-1-
-0-
Automatic start inhibited,
flying-restart circuit inactive
-1-
Automatic start, if term. 28 HIGH,
flying-restart circuit not active
-2-
Automatic start inhibited,
flying-restart circuit active
-3-
Automatic start, if term. 28 HIGH,
flying-restart circuit active
C144
¿ Chopper-frequency
reduction
821X/822X/824X
-1-
-0-
No chopper-frequency reduction
-1-
Automatic chopper-frequency
lowering when
J
max
- 10
°C
C161* Current fault
Only display
C162* Last fault
Only display
C163* Last but one fault
Only display
C164* Last but two fault
Only display
C170
¿ TRIP-reset selection
-0-
TRIP-reset by pressing the STP key
or LOW signal at ctrl. enable
-1-
Auto-TRIP-Reset
C171 Delay for
Auto-TRIP-Reset
0
0
{1s}
60
C178* Operating time
Only display
C179* Mains switch-on
time
Only display
C377 Gain Zk-voltage
detection
822X/824X
Should only be
changed by the
Lenze Service!
C500* Display factor
application datum
numerator
821X/822X/824X
2000
1
{1}
25000
C501* Display factor for
process variable
denominator
821X/822X/824X
10
1
{1}
25000