Configuration – Lenze 8240 frequency inverters User Manual
Page 47
![background image](/manuals/566200/47/background.png)
Configuration
UOOu_^MTMO
7-3
L
Code
IMPORTANT
Possible settings
Name
Code
IMPORTANT
Info
Selection
Lenze
Name
[C007]* Terminal
configuration
-0-
E4
E3
E2
E1
-0- CW/CCW DC brake
JOG1/2/3
-1- CW/CCW
PAR
JOG1/2/3
-2- CW/CCW
QSP
JOG1/2/3
-3- CW/CCW
PAR DC brake JOG1
-4- CW/CCW
QSP
PAR
JOG1
-5- CW/CCW DC brake Trip set JOG1
-6- CW/CCW
PAR
Trip set JOG1
-7- CW/CCW
PAR DC brake Trip set
-8- CW/CCW
QSP
PAR
Trip set
-9- CW/CCW
QSP
Trip set JOG1
-10- CW/CCW Trip set
UP
DOWN
-11- CW/CCW DC brake
UP
DOWN
-12- CW/CCW
PAR
UP
DOWN
-13- CW/CCW
QSP
UP
DOWN
-14- CCW/QSP CW/QSP DC brake JOG1
-15- CCW/QSP CW/QSP
PAR
JOG1
-16- CCW/QSP CW/QSP
JOG1/2/3
-17- CCW/QSP CW/QSP
PAR
DC brake
-18- CCW/QSP CW/QSP
PAR
Trip set
-19- CCW/QSP CW/QSP DC brake Trip set
-20- CCW/QSP CW/QSP Trip set JOG1
-21- CCW/QSP CW/QSP
UP
DOWN
-22- CCW/QSP CW/QSP
UP
JOG1
D
CW =
CW rotation
D
CCW =
CCW rotation
D
DC brake =
DC injection brake
D
PAR =
Change of
parameter sets
D
JOG =
JOG frequency
D
QSP =
Quick stop
D
Trip-Set =
External fault
D
UP/DOWN =
Motor potentiometer
functions
C008
¿ Function relay K1
-1-
-0-
Ready for operation
-1-
TRIP fault message
-2-
Motor is running
-3-
Motor is running / CW rotation
-4-
Motor is running / CCW rotation
-5-
Field frequency f
d
= 0
-6-
f
dset
reached
-7-
Q
min
reached
-8-
I
max
reached
-9-
Overtemperature (
J
max
-10
°C)
-10-
TRIP or Q
min
or IMP
C009* Device address
1
1
{1}
99
Only for LECOM
applications
C010 Minimum field
frequency
0.0
0.0
{0.1Hz}
480.0
C011 Maximum field
frequency
820X
50.0
30.0
{0.1Hz}
480.0
821X
50.0
7.5
{0.1Hz}
480.0
30.0
{0.1Hz}
480.0
(Software 2x)
(Software 1x)
822X/824X
50.0
7.5
{0.1Hz}
480.0
C012 Acceleration time
5.0
0.0
{0.1s}
999.0
C013 Deceleration time
5.0
0.0
{0.1s}
999.0
Show/Hide Bookmarks