2 control word, Control word, Parameter setting – Lenze EMF2112IB User Manual
Page 38

Parameter setting
6-16
BA2112EN
6.1.3.2
Control word
Bit
Name
Meaning
0
Switch on
0 = command 2, 6, 8 (controller inhibit)
1 = command 3 (controller inhibit)
1
Voltage inhibit
0 = Voltage inhibit active
1 = voltage inhibit not active
2
Quick stop
0 = Quick stop active
1 = Quick stop not active
3
Operation enable
0 = Operation inhibited
1 = Operation enabled
4
RFG inhibit
Inhibit of the ramp-funtion generator.
Quick stop is activated without the controller leaving its status.
0 = RFG inhibit (quick stop)
1 = RFG inhibit not active
5
RFG-stop
820X:
Reserved
821X, 822X:
Output of the RFG (speed setpoint integrator) is ”frozen”.
0 = RFG stop
1 = RFG stop not active
8200 vector, 93XX:
free. Mapping to bit AIF-CTRL.B4 negated.
6
RFG-zero
820X:
Reserved
821X, 822X:
Input of the ramp function generator (speed setpoint integrator) is set to 0. Thus
controlled deceleration along the ramp.
0 = RFG zero
1 = RFG zero not active
8200 vector, 93XX:
free. Mapping to bit AIF-CTRL.B5 negated.
7
Fault reset
Fault reset (TRIP). For this, a bit change from 0 to 1 is required.
For 82XX, the controller is initialized.
During this time, the controller does not accept any commands.
8 .. 9 Reserved
11
Manufacturer
820X, 821x, 822x:
Reserved
8200 vector, 93XX:
free. Mapping to bit AIF-CTRL.B7 1) .
12
Manufacturer
820X, 821x, 822x:
Parameter set changeover:
0 – 1 = Parameter set 2
1 – 0 = Parameter set 1
8200 vector, 93XX:
free. Mapping to bit AIF-CTRL.B12 1) .
13
Manufacturer
820X, 821x, 822x:
DC-injection brake:
0 = DCB not active
1 = DCB active
8200 vector, 93XX:
free. Mapping to bit AIF-CTRL.B13 1) .
14
Manufacturer
820X, 821x, 822x:
Reserved
8200 vector, 93XX:
free. Mapping to bit AIF-CTRL.B14 1) .
15
Manufacturer
820X:
PI - inhibit
Inhibit the update of the PO data of the controller (input data for the master).
Updates for status and actual information of the process channel can be inhibited
to transfer control information timed more accurately (see chapter 3.6.2).
0 = Read status and actual value
1 = Do not read status and actual value
821X,822X:
Reserved
8200 vector, 93XX:
free. Mapping to bit AIF-CTRL.B15 1) .
Signal configuration C0005
Bit 5
(AIF-CTRL.B4)
Bit 6
(AIF-CTRL.B5)
Bit 11
(AIF-CTRL.B7)
Bit 12
(AIF-CTRL.B12)
Bit 13
(AIF-CTRL.B13)
Bit 14
(AIF-CTRL.B1
4)
Bit 15
(AIF-CTRL.B15)
Speed control 1003 / 1013 /
1113
NSET-RFG-STOP
(RFG stop)
NSET-RFG-0
(RFG zero)
Reserved
DCTRL-PAR*1
DCTRL-PAR-
LOAD
NSET-
TI*1
NSET-
TI*2
Torque
control
4003 / 4013 /
4113
NSET-RFG-STOP
(RFG stop)
NSET-RFG-0
(RFG zero)
Reserved
DCTRL-PAR*1
DCTRL-PAR-
LOAD
NSET-JOG*1
NSET-JOG*2
DF master
5003 / 5013 /
5113
NSET-RFG-STOP
(RFG stop)
NSET-RFG-0
(RFG zero)
Reserved
DCTRL-PAR*1
DCTRL-PAR-
LOAD
REF-ON
NSET-TI*1
DF-slave bus
6003 / 6013 /
6113
Reserved
Reserved
Reserved
DCTRL-PAR*1
DCTRL-PAR-
LOAD
REF-ON
Reserved
DF-slave
cascade
7003 / 7013 /
7113
Reserved
Reserved
Reserved
DCTRL-PAR*1
DCTRL-PAR-
LOAD
REF-ON
Reserved
Cam profiler
1xxx3
CSEL1-EVENT
CDATA-CYCLE
CSEL1-LOAD
Reserved
Reserved
Reserved
Reserved
Positioning
2xxx3
POS-PRG-START POS-PRG-STOP POS-PRG-
RESET
POS-PS-CANCEL
POS-PARAM-RD
POS-LOOP-
INH
POS-STBY-STP
Show/Hide Bookmarks