2 mechanical installation, 3 electrical installation, 1 voltage supply – Lenze EMF2112IB User Manual
Page 14: 2 features, Mechanical installation, Electrical installation, Voltage supply, Features, Installation

Installation
4-2
BA2112EN
4.2
Mechanical installation
•
If necessary, remove the keypad which was previously attached to the controller before.
•
Plug the 2112 fieldbus module into the corresponding interface of the controller and fasten it
with the fixing screw (see Fig. 4-1).
Tighten the screws to ensure a good PE connection.
4.3
Electrical installation
Tip!
The communciation of 820X and 821X controllers may be disrupted by electromagnetic radiation.
If necessary, use an additional PE screen cable.
4.3.1
Voltage supply
No special or external voltage supplies necessary. The 2112 fieldbus module is supplied via
INTERBUS-Loop.
4.3.2
Features:
Communication medium
INTERBUS-Loop
Network topology
Ring
Possible number of controllers
– Max. load capacity of the loops:
1.8 A
– Current consumption per 2112 fieldbus
module:
50 mA
Å
Max. number of participants:
36
Max. loop length
200 m
Distance between fieldbus modules
20 m
Maximum baud rate
500 kbit/s
For an example of the INTERBUS structure, see the drawing (Fig. 4-2). The accessories required
(INTERBUS Loop terminal) are listed in chapter 8.