2 status word, Status word, Parameter setting – Lenze EMF2112IB User Manual
Page 32

Parameter setting
6-10
BA2112EN
6.1.2.2
Status word
Status word for 82XX and 8200 vector
820X
821x,822x
8200vector
Lenze setting
0
Reserved
Actual parameter set
0 = Parameter set 1 or 3 active
1 = Parameter set 2 or 4 active
DCTRL-PAR-B0
1
IMP (pulse inhibit)
0 = Pulses for power stage enabled
1 = Pulses for power stage inhibited
IMP (pulse inhibit)
0 = Pulses for power stage enabled
1 = Pulses for power stage inhibited
DCTRL1-IMP
2
I
max
(current limit reached)
0 = Current limit not reached
1 = current limit reached
I
max
(current limit reached)
0 = Current limit not reached
1 = current limit reached
MCTRL1-IMAX
3
Reserved
f
d
= f
dset
0 = f
d
≠
f
dset
1 = f
d
= f
dset
MCTRL1-RFG1= NOUT
4
f
d
= f
dset
0 = f
d
≠
f
dset
1 = f
d
= f
dset
RFG on = RFG off
0 = RFG on
≠
RFG off
1 = RFG on = RFG out
NSET1-RFG1-I= 0
5
Qmin (f
d
≤
f
dQmin
)
0 = Qmin not active
1 = Qmin active
Qmin (f
d
≤
f
dQmin
)
0 = Qmin not active
1 = Qmin active
PCTRL1-QMIN
6
f
d
= 0 (act. frequency = 0)
0 = f
d
≠
0
1 = f
d
= 0
f
d
= 0 (act. frequency = 0)
0 = f
d
≠
0
1 = f
d
= 0
DCTRL1-NOUT= 0
7
Ctrl. inhibit (controller inhibit)
0 = controller not inhibited
1 = controller inhibited
Ctrl. inhibit (controller inhibit)
0 = controller not inhibited
1 = controller inhibited
DCTRL1-CINH
8...11 Unit status
0 = No error
8 = Error active
Unit status
0 = Controller initialization
1 = Switch on inhibit
3 = Operation inhibited
4 = Flying-restart circuit active
5 = DC brake active
6 = Operation enabled
7 = Message active
8 = Fault active
Unit status
0 = Controller initialization
1 = Switch on inhibit
3 = Operation inhibited
4 = Flying-restart circuit active
5 = DC brake active
6 = Operation enabled
7 = Message active
8 = Fault active
12
Overtemperature warning (
ϑ
max
- 10°C)
0 = No warning
1 = Warning
Overtemperature warning
0 = No warning
1 = Warning
DCTRL1-OH-WARN
13
U
Gmax
(DC-bus overvoltage)
0 = No overvoltage
1 = overvoltage
U
Gmax
(DC-bus overvoltage)
0 = No overvoltage
1 = overvoltage
DCTRL1-OV
14
Direction of rotation
0 = CW rotation
1 = CCW rotation
Direction of rotation
0 = CW rotation
1 = CCW rotation
DCTRL1-CCW
15
Ready for operation
0 = not ready for operation
1 = ready for operation
Ready for operation
0 = not ready for operation
1 = ready for operation
DCTRL1-RDY