C14004
C14005
C14006
Parameter | Name:
C14004 | Resolved IP-Adress
Data type: UNSIGNED_8
Index: 10571
d
= 294B
h
The IP address is required for addressing the Servo Drive 9400 if communication between the PC and the controller
is to be established via an Ethernet connection.
• The IP address consists of four numbers from 0 to 255 which can be set in the four subcodes.
• The first one, two, or three numbers indicate the network (Net-ID), the remaining numbers indicate the host
(Host-ID). The definite specification of the part that is to be evaluated as Net-ID is effected in
(Ethernet:
Subnetwork mask).
Display range
(min. value | unit | max. value)
0
255
Subcodes
Info
C14004/1
IP address
• Sequence: "[1].[2].[3].[4]"
C14004/2
C14004/3
C14004/4
;
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C14005 | Use of DHCP
Data type: UNSIGNED_8
Index: 10570
d
= 294A
h
This code is available for Servo Drives 9400 of version V03.00.00.00 or higher.
You use this code to define whether DHCP is to be used or not.
DHCP implementation in the Servo Drive 9400 ( 34)
Selection list
(Lenze setting printed in bold)
0 Do not use DHCP
1 Use DHCP
;
Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C14006 | Ethernet node state
Data type: UNSIGNED_8
Index: 10569
d
= 2949
h
Indicates if an error has occurred or a telegram has been lost during Ethernet communication.
Selection list
(read only)
0 No error
1 Error, frame lost
;
Read access Write access CINH PLC STOP No transfer