9 parameter reference, C00615 | resp. to imp. device config, C00636 | resp. to new module in mxi1 – Lenze E94AYCEN User Manual
Page 54: Parameter reference, Parameter reference ( 54), Supplemented, Communication, E94aycen communication manual (ethernet), 9parameter reference

E94AYCEN communication manual (Ethernet)
Parameter reference
Parameters of the standard device that are relevant to communication
54
L
EDS94AYCEN EN 9.0 - 09/2012
9
Parameter reference
This chapter supplements the parameter list and the table of attributes in the software
manual and in the »Engineer« online help for the Servo Drive 9400 by the parameters of
the E94AYCEN communication module (Ethernet).
9.1
Parameters of the standard device that are relevant to communication
In this chapter communication-relevant parameters of the Servo Drive 9400 are listed in
numerically ascending order.
C00615
C00636
Software manual/»Engineer« online help for the Servo Drive 9400
Here you will find general information on parameters.
Parameter | Name:
C00615 | Resp. to imp. device config.
Data type: UNSIGNED_32
Index: 23960
d
= 5D98
h
Response to impermissible device configuration
Selection list
1 Fault
3 Quick stop by trouble
4 Warning Locked
6 Information
0 No Response
Subcodes
Lenze setting
Info
C00615/1
0: No Response
Reserved
C00615/2
0: No Response
Resp. to imp. module in MXI1
C00615/3
0: No Response
Resp. to imp. module in MXI2
C00615/4
0: No Response
Reserved
C00615/5
0: No Response
Reserved
;
Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C00636 | Resp. to new module in MXI1
Data type: UNSIGNED_32
Index: 23939
d
= 5D83
h
Response if a new module has been plugged into module slot 1 of the standard device.
Selection list
(Lenze setting printed in bold)
1 Fault
6 Information
5 Warning
4 Warning Locked
3 Quick stop by trouble
0 No Response
;
Read access ; Write access CINH PLC STOP No transfer