C13002 | ethernet gateway address, C13003 | ethernet: mac-id, C13002/1 – Lenze E94AYCEN User Manual
Page 57: C13003/1, C13002/2, C13002/3, C13002/4, C13003, C13003/2, C13003/3

EDS94AYCEN EN 9.0 - 09/2012
L
57
E94AYCEN communication manual (Ethernet)
Parameter reference
Parameters of the communication module for slot MXI1
C13002
C13003
Parameter | Name:
C13002 | Ethernet gateway address
Data type: UNSIGNED_8
Index: 11573
d
= 2D35
h
The gateway address is required if the Servo Drive 9400 is not located in the same subnetwork as the PC.
• The gateway address consists of four numbers from 0 to 255 which can be set in the four subcodes.
Setting range
(min. value | unit | max. value)
0
255
Subcodes
Lenze setting
Info
C13002/1
127
Gateway address
• Sequence: "[1].[2].[3].[4]"
• Lenze setting: "127.0.0.1"
C13002/2
0
C13002/3
0
C13002/4
1
;
Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C13003 | Ethernet: MAC-ID
Data type: UNSIGNED_8
Index: 11572
d
= 2D34
h
The MAC-ID is a globally unique identifier of an Ethernet-capable device. The MAC-ID is assigned by the
manufacturer and permanently burnt into the device (Lenze communication module).
• The MAC-ID consists of six numbers from 0 to 255 which are displayed in the six subcodes.
Display range
(min. value | unit | max. value)
0
255
Subcodes
Info
C13003/1
MAC-ID
• Sequence: "[1]-[2]-[3]-[4]-[5]-[6]"
C13003/2
C13003/3
C13003/4
C13003/5
C13003/6
;
Read access Write access CINH PLC STOP No transfer