C14000 | ethernet: ip address, C14001 | ethernet: subnetwork mask, C14000/1 – Lenze E94AYCEN User Manual
Page 60: C14001/1, C14000/2, C14000/3, C14000/4, C14001/2, C14001/3, C14001/4

E94AYCEN communication manual (Ethernet)
Parameter reference
Parameters of the communication module for slot MXI2
60
L
EDS94AYCEN EN 9.0 - 09/2012
9.3
Parameters of the communication module for slot MXI2
This chapter lists, in ascending numerical order, the parameters of the E94AYCEN
(Ethernet) communication module for slot MXI2 of the Servo Drive 9400.
C14000
C14001
Parameter | Name:
C14000 | Ethernet: IP address
Data type: UNSIGNED_8
Index: 10575
d
= 294F
h
The IP address is required for addressing the Servo Drive 9400 if communication between the PC and the controller
is to be established via an Ethernet connection.
• The IP address consists of four numbers from 0 to 255 which can be set in the four subcodes.
• The first one, two, or three numbers indicate the network (Net-ID), the remaining numbers indicate the host
(Host-ID). The definite specification of the part that is to be evaluated as Net-ID is effected in
(Ethernet:
Subnetwork mask).
Setting range
(min. value | unit | max. value)
0
255
Subcodes
Lenze setting
Info
C14000/1
127
IP address
• Sequence: "[1].[2].[3].[4]"
• Lenze setting: "127.0.0.1"
C14000/2
0
C14000/3
0
C14000/4
1
;
Read access ; Write access CINH PLC STOP No transfer
Parameter | Name:
C14001 | Ethernet: Subnetwork mask
Data type: UNSIGNED_8
Index: 10574
d
= 294E
h
The subnet mask indicates which part of the IP address is evaluated as Net-ID and which part as Host-ID.
• The subnet mask consists of four numbers from 0 to 255 which can be set in the four subcodes.
Setting range
(min. value | unit | max. value)
0
255
Subcodes
Lenze setting
Info
C14001/1
255
Subnet mask
• Sequence: "[1].[2].[3].[4]"
• Lenze setting: "255.255.255.0" (The first three bytes
of the IP address are the Net-ID.)
C14001/2
255
C14001/3
255
C14001/4
0
;