E94aycen communication manual (ethernet), Parameter data transfer telegram examples – Lenze E94AYCEN User Manual
Page 47

EDS94AYCEN EN 9.0 - 09/2012
L
47
E94AYCEN communication manual (Ethernet)
Parameter data transfer
Telegram examples
7.7.2
Example 2: Querying the firmware product type (read request)
The firmware product type of the controller is to be read.
Code to be read: C00200
Assumption: product type = "E94AFH"
Request
SDO command (GSV) = 0x82 = "Read parameter"
GCI message qualifier (GMQ) = 0x00 = 00000000B = "Request"
Transaction ID (GTI) here "1" (optional consecutive number 0 ... 255)
Length of the user data (SIZE) = 0x0014 = 20 bytes
GCI header
GMT
GSV
GMQ
GTI
SIZE
SIZE
res
res
0x01
0x82
0x00
0x01
0x14
0x00
0x00
0x00
Fixed
Reading
parameters
Request
Transactions ID
Length of the user data = 20 bytes
Reserved
User data area P0
Byte 1
Byte 2
Byte 3
Byte 4
Reserved
Reserved
Data type
Reserved
0x00
0x00
0x00
0x00
Optional for
read request
User data area P1
User data area P2
Byte 1
Byte 2
Byte 3
Byte 4
Byte 1
Byte 2
Byte 3
Byte 4
Code
Reserved
Reserved
Subcode
Reserved
Reserved
0xC8
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Code = 200 = 0x00C8
Subcode = 0
User data area P3
User data area P4
Byte 1
Byte 2
Byte 3
Byte 4
Byte 1
Byte 2
Byte 3
Byte 4
Reserved
Reserved
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00