Parameter reference
Parameters of the communication module for slot MXI1
C13007
C13008
Parameter | Name:
C13007 | Resolved Subnetmask
Data type: UNSIGNED_8
Index: 11568
d
= 2D30
h
The subnet mask indicates which part of the IP address is evaluated as Net-ID and which part as Host-ID.
• The subnet mask consists of four numbers from 0 to 255 which can be set in the four subcodes.
Display range
(min. value | unit | max. value)
0
255
Subcodes
Info
C13007/1
Subnet mask
• Sequence: "[1].[2].[3].[4]"
C13007/2
C13007/3
C13007/4
;
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C13008 | Resolved Gateway-Address
Data type: UNSIGNED_8
Index: 11567
d
= 2D2F
h
The gateway address is required if the Servo Drive 9400 is not located in the same subnetwork as the PC.
• The gateway address consists of four numbers from 0 to 255 which can be set in the four subcodes.
Display range
(min. value | unit | max. value)
0
255
Subcodes
Info
C13008/1
Gateway address
• Sequence: "[1].[2].[3].[4]"
C13008/2
C13008/3
C13008/4
;