beautypg.com

4 technical data, General data, Technical data – Lenze E94AYCIB User Manual

Page 36: 4technical data

background image

4

Technical data

General Data

EDK94AYCIB DE/EN/FR/ES/IT 1.0

36

l

H1_Daten−GHB Servo Drives 9400

4

Technical data

General Data

Range

Values

Order designation

E94AYCIB

Communication profile

INTERBUS

Interfaces

l

Input (IN): 9−pin Sub−D connector

l

Input (OUT): 9−pin Sub−D socket

Communication medium

RS485

Network topology

Ring

Number of INTERBUS nodes

l

1 master

l

512 slaves

Baud rate

500 kBit/s or 2 MBit/s
(adjustable by means of DIP switches or codes)

Max. cable length

l

400 m at 500 kBit/s

l

150 m at 2 MBit/s

(between each of the individual INTERBUS nodes)

INTERBUS node

Slave

Voltage supply

External supply via the 2−pin plug connector

l

"+": U = 24 V DC (+/− 10 %), Imax = 180 mA

l

"−": reference potential for external voltage supply

Conformities, approvals

CE

,

"Servo Drives 9400" hardware manual

Here you can find the ambient conditions and the electromagnetic
compatibility (EMC) specifications applying to the communication module.