5 feedback system, Feedback system, Electrical installation – Lenze MDFQA Operating Instructions User Manual
Page 35

Electrical installation
Terminal box
Feedback system
EN
35
Lenze ¯ BA 33.0006 ¯ 3.0
6.4.5
Feedback system
Resolver
Terminal
Designation
Meaning
B1
B2
+Ref
−Ref
Transformer windings
(reference windings)
B3
+ VCC ENP
Supply: electronic
nameplate
1)
B4
B5
+COS
−COS
Stator winding cosine
B6
B7
+SIN
−SIN
Stator winding sine
B8
Not assigned
R1
R2
+KTY
−KTY
Thermal sensor KTY
1) Only for versions with electronic nameplate ENP.
Incremental encoder / sin/cos absolute value encoder with Hiperface
Terminal
Designation
Meaning
B1
B2
+ U
B
GND
Supply +
Mass
B3
B4
A
A
Track A / + COS
Track A inverse / − COS
B5
B6
B
B
Track B / + SIN
Track B inverse / − SIN
B7
B8
Z
Z
Zero track / + RS485
Zero track inverse / − RS485
B10
Shield − housing
Shield − incremental encoder
R1
R2
+KTY
−KTY
Thermal sensor KTY
Sin/cos absolute value encoder with EnDat interface
Terminal
Designation
Meaning
B1
+ U
B
Supply + / + VCC ENP
1)
B2
GND
Mass
B3
B4
A
A
Track A
Track A inverse
B5
B6
B
B
Track B
Track B inverse
B7
B8
Data
Data
Data EnDat interface
Data inverse EnDat interface
B20
B21
Cycle
Cycle
Clock pulse EnDat interface
Clock pulse inverse EnDat interface
B22
UP sensor
UP sensor
B23
0 V sensor
0 V sensor
B24
Shield
Shield for housing of encoder
B25
Not assigned
R1
R2
+KTY
−KTY
Thermal sensor KTY
1) Only for versions with electronic nameplate ENP.