4 technical data, 1 general data and operating conditions, Technical data – Lenze MDFQA Operating Instructions User Manual
Page 19: General data and operating conditions

Technical data
General data and operating conditions
4
EN
19
Lenze ¯ BA 33.0006 ¯ 3.0
4
Technical data
4.1
General data and operating conditions
General data
Conformity
CE
2006/95/EC
Low−Voltage Directive
Approvals
UL
ANSI/UL 1004−1
ANSI/UL 1004−6
Rotating Electrical Machines
Servo and Stepper Motors
CSA
CSA−C22.2 No. 100
Motors and Generators
Protection of persons and devices
Enclosure
See nameplate
Degrees of protection only apply to horizontal installation
All unused connectors must be closed with protection
covers or blanking plugs.
Temperature class
F (155 °C) IEC 60034 Exceedance of the temperature limit weakens or destroys
the insulation
Permissible voltage
According to limiting curve A of the pulse voltage from
IEC / TS 60034−25 (image 14)
EMC
Noise emission
IEC/EN 61800−3
Depending on the controller, see documentation for the
controller.
Noise immunity
Operating conditions
Ambient conditions
Climatic
Transport
IEC/EN 60721−3−2
2K3 (−20 °C ... +70 °C)
Storage
IEC/EN 60721−3−1
1K3 (−20 °C ... +60 °C)
< 3 months
1K3 (−20 °C ... +40 °C)
> 3 months
Operation
IEC/EN 60721−3−3
3K3 (−20 °C ... +40 °C)
Without brake
3K3 (−10 °C ... +40 °C)
With brake
3K3 (−15 °C ... +40 °C)
with blower
> +40 °C
with power reduction, see
catalogue
Site altitude
< 1000 m amsl − without power reduction
> 1000 m amsl < 4000m amsl with power reduction, see
catalogue
Humidity
Relative humidity
£ 85 %, without condensation
Electrical
The motor connection type depends on the controller
Length of the motor cable
See inverter instructions
Length of cable for speed feedback
Mechanical
IEC/EN60721−3−3
3M6