Safety instructions
Residual hazards
EN
11
Lenze ¯ BA 33.0006 ¯ 3.0
Motor protection
¯
Installed thermal detectors are no full protection for the machine.
–
If required, limit the maximum current, parameterise the controller such that it
will be switched off after some seconds of operation with I > I
N
, especially if
there is the danger of blocking.
–
Installed overload protection does not prevent an overload under any
conditions.
¯
Installed brakes are no fail−safe brakes.
–
The torque can be reduced due to disruptive factors that cannot be influenced,
e.g. by ingressing oil due to a defect shaft sealing ring on the A side.
¯
Fuses are no motor protection.
–
Use current−dependent motor protection switches at average operating
frequency.
–
Use installed thermal detectors at high operating frequency.
¯
Too high torques cause a fraction of the motor shaft.
–
The maximum torques according to catalogue must not be exceeded.
¯
Lateral forces from the motor shaft may occur.
–
Align shafts of motor and driving machine exactly to each other.
¯
If deviations from normal operation occur, e.g. increased temperature, noise,
vibration, determine the cause and, if necessary, contact the manufacturer. If in
doubt, switch off the motor.
Fire protection
¯
Fire hazard
–