JULABO FPW50-MA Refrigerated and Heating Circulators User Manual
Page 20

Operator responsibility – Safety recommendations
20
FP40-MA
Working temperature range
°C
-40 ... 200
Temperature stability
°C
±0,02
Cooling capacity
Medium ethanol
°C
kW
+20 0 -20 -30 -40
0.68 0.5 0.32 0.17 0.04
Refrigerant
R404A
Overall dimensions
(WxDxH)
cm
37x46x69
Bath opening
(WxL)
cm
23x14
Bath depth
cm
20
Filling volume
from ... to
liters
9 ... 16
Weight
kg
48
Mains power connection
230 V/50 Hz
V/ Hz
207-253 / 50
Current draw
(at 230 V)
A
13
Current draw
CH (at 230 V)
A
9+3
Mains power connection
230 V/60 Hz
V/ Hz
207-253 / 60
Current draw
(at 230 V)
A
13
FP50-MA / FPW50-MA
Working temperature range
°C
-50 ... 200
Temperature stability
°C
±0,02
Cooling capacity
Medium ethanol
°C
kW
+20 0 -20 -30 -40
0.9 0.8 0.5 0.32 0.16
Refrigerant
R404A / R507
Overall dimensions
(WxDxH)
cm
42x49x70
Bath opening
(WxL)
cm
18x12
Bath depth
cm
15
Filling volume
from ... to
liters
5,5 ... 8
Weight
kg
55
Mains power connection
230 V/50 Hz
V/ Hz
207-253 / 50
Current draw
(at 230 V)
A
14
Current draw
CH (at 230 V)
A
9+4
Mains power connection
230 V/60 Hz
V/ Hz
207-253 / 60
Current draw
(at 230 V)
A
14
All measurements have been carried out at: rated voltage and frequency
ambient temperature: 20 °C
Technical changes without prior notification reserved.
- FP50-MA Refrigerated and Heating Circulators FP40-MA Refrigerated and Heating Circulators FP35-MA Refrigerated and Heating Circulators F34-MA Refrigerated and Heating Circulators F32-MA Refrigerated and Heating Circulators F33-MA Refrigerated and Heating Circulators F25-MA Refrigerated and Heating Circulators F12-MA Refrigerated and Heating Circulators