Report Date : 10/02/2012

7

/

4

Revision 7

DC1 - VERICLEAN FLUX REMOVER, AEROSOL

7.2. Conditions for safe storage, including any incompatibilities

Aerosol cans: Must not be exposed to direct sunlight or temperatures above 50°C.

7.3. Specific end use(s)

Cleaning agent.

SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION

8.1. Control parameters

STD

STEL - 15 Min

TWA - 8 Hrs

Name

Notes

100
ppm(Sk)

375
mg/m3(Sk)

WEL

150
ppm(Sk)

560
mg/m3(Sk)

1-METHOXY-2-PROPANOL

WEL = Workplace Exposure Limit.

Ingredient Comments
WEL = Workplace Exposure Limits

8.2. Exposure controls

Protective equipment

Engineering measures
Provide adequate general and local exhaust ventilation.
Respiratory equipment
No specific recommendation made, but respiratory protection must be used if the general level exceeds the recommended occupational
exposure limit.
Hand protection
For prolonged or repeated skin contact use suitable protective gloves. Gloves of nitrile rubber, PVA or Viton are recommended.
Eye protection
Use eye protection. Wear approved, tight fitting safety glasses where splashing is probable.
Other Protection
Wear appropriate clothing to prevent any possibility of liquid contact and repeated or prolonged vapour contact.
Hygiene measures
DO NOT SMOKE IN WORK AREA! Wash at the end of each work shift and before eating, smoking and using the toilet. Promptly remove
any clothing that becomes contaminated. When using do not eat, drink or smoke.

SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES

9.1. Information on basic physical and chemical properties

Appearance

Liquid

Colour

Clear Colourless.

Odour

Slight odour. Ether.

Solubility

Not soluble in water.

Initial boiling point and boiling range 98 C / 210 F
Vapour density (air=1)

> 1.0

Vapour pressure

44.6 mm Hg 25

Flash point (°C)

3.0 C / 37.0 F TCC (Tag closed cup).

Auto Ignition Temperature (°C)

689 C / 365 C

Flammability Limit - Lower(%)

1.25

Flammability Limit - Upper(%)

18.6

Comments

Aerosol.

9.2. Other information

Documentation Provided By HMC Electronics

33 Springdale Ave. Canton, MA 02021

http://www.hmcelectronics.com

(800) 482-4440