8
/
4
Revision 6
CCC Contact Cleaner C
Provide good ventilation. Avoid inhalation of vapours/spray and contact with skin and eyes. Avoid contact with naked flames and hot
surfaces as corrosive and toxic decomposition products can be formed. Keep out of the reach of children.
7.2. Conditions for safe storage, including any incompatibilities
Aerosol cans: Must not be exposed to direct sunlight or temperatures above 50°C. Keep upright.
7.3. Specific end use(s)
The identified uses for this product are detailed in Section 1.2.
SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION
8.1. Control parameters
STD
STEL - 15 Min
TWA - 8 Hrs
Name
Notes
500 ppm
1210 mg/m3
WEL
1500 ppm
3620 mg/m3
ACETONE
WEL = Workplace Exposure Limit.
8.2. Exposure controls
Protective equipment
Engineering measures
No specific ventilation requirements noted, except this product must not be used in a confined space without good ventilation.
Respiratory equipment
Considering the size of the packaging, the risk is regarded as minimal. Vapours are heavier than air and may travel along the floor and in
the bottom of containers. At work in confined or poorly ventilated spaces, respiratory protection with air supply must be used.
Self-contained breathing apparatus with full facepiece.
Hand protection
For prolonged or repeated skin contact use suitable protective gloves. Gloves of nitrile rubber, PVA or Viton are recommended.
Eye protection
Wear approved, tight fitting safety glasses where splashing is probable.
Other Protection
Wear suitable protective clothing as protection against splashing or contamination.
Hygiene measures
No specific hygiene procedures noted, but good personal hygiene practices are always advisable, especially when working with
chemicals. When using do not eat, drink or smoke.
Skin protection
Wear apron or protective clothing in case of splashes.
SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES
9.1. Information on basic physical and chemical properties
Appearance
Clear liquid. Aerosol.
Colour
Colourless.
Odour
Slight odour. Ether
Solubility
Slightly soluble in water.
Initial boiling point and boiling range 44 C / 111 F
Vapour density (air=1)
4
Vapour pressure
47 kPa 20
Flammability Limit - Lower(%)
5.5
Flammability Limit - Upper(%)
9.0
Other Flammability
This product is not flammable.