Material safety data sheet – HMC Electronics 2509-GN Techspray Trace Tech Overcoat Pen User Manual
Page 3
![background image](/manuals/562005/3/background.png)
MATERIAL SAFETY DATA SHEET
Finished Product
Date Issued: 01/18/2003
MSDS No: 2509-GN
Date Revised: 08/17/2010
Revision No: 5
Trace Technologies Overcoat Pen (Green)
should be permitted in area. See Section 8 for details.
7. HANDLING AND STORAGE
GENERAL PROCEDURES: Wash thoroughly after handling. Use only in a well ventilated area. Store in a cool dry
place.
HANDLING: Use with sufficient ventilation to keep employee exposure below recommended limits. Provide
adequate ventilation for storage, handling and use, especially for enclosed or low spaces. Avoid contact of liquid
with eyes and prolonged skin exposure. Do not allow product to contact open flame or electrical heating elements
because dangerous decomposition products may form.
STORAGE: Store away from heat.
STORAGE TEMPERATURE: Store in a cool place below ( 120 ) F (49 ) C.
STORAGE PRESSURE: Store at local atmospheric pressure.
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
EXPOSURE GUIDELINES
OSHA HAZARDOUS COMPONENTS (29 CFR1910.1200)
EXPOSURE LIMITS
OSHA PEL
ACGIH TLV
SupplierOEL
Chemical Name
ppm
mg/m
3
ppm
mg/m
3
ppm
mg/m
3
Acetone
TWA
750
ppm
[1]
1800
mg/m3
[1]
750
ppm
1780
mg/m3
NL ppm
NL
mg/m3
STEL
1000
ppm
2400
mg/m3
1000
ppm
2380
mg/m3
NL ppm
NL
mg/m3
n-Propyl acetate
TWA
200 ppm
200
ppm
STEL
250 ppm
250
ppm
OSHA TABLE COMMENTS:
1. NL = Not Listed
ENGINEERING CONTROLS: Use process enclosures, local exhaust ventilation, or other engineering controls to
control airborne levels below recommended exposure limits.
PERSONAL PROTECTIVE EQUIPMENT
EYES AND FACE: For normal conditions, wear safety glasses. Where there is reasonable probability of liquid
contact, wear splash-proof goggles.
SKIN: The glove(s) listed below may provide protection against permeation. Gloves of other chemically
resistant materials may not provide adequate protection. Viton, Solvex, Butyl, Buna, Neoprene.
RESPIRATORY: NIOSH/MSHA approved air purifying respirator with an organic vapor cartridge or canister may
be permissible under certain circumstances where airborne concentrations are expected to exceed exposure
limits. Protection provided by air purifying respirators is limited. Use a positive pressure air supplied respirator
if there is any potential for an uncontrolled release, exposure levels are not known, or any other circumstances
Page 3 of 7
Documentation Provided By HMC Electronics
33 Springdale Ave. Canton, MA 02021
(800) 482-4440