beautypg.com

HMC Electronics 68035 Loctite 680 Retaining Compound, High Strength User Manual

Page 3

background image

TDS LOCTITE

®

680™, December

-

2009

GENERAL INFORMATION
This product is not recommended for use in pure oxygen

and/or oxygen rich systems and should not be selected as

a sealant for chlorine or other strong oxidizing materials

For safe handling information on this product, consult the

Material Safety Data Sheet (MSDS).

Where aqueous washing systems are used to clean the

surfaces before bonding, it is important to check for

compatibility of the washing solution with the adhesive. In

some cases these aqueous washes can affect the cure and

performance of the adhesive.

This product is not normally recommended for use on plastics

(particularly thermoplastic materials where stress cracking of

the plastic could result). Users are recommended to confirm

compatibility of the product with such substrates.

Directions for use:
For Assembly

1. For best results, clean all surfaces (external and internal)

with a LOCTITE

®

cleaning solvent and allow to dry.

2. If the material is an inactive metal or the cure speed is too

slow, spray with Activator 7471™ or 7649™ and allow to

dry.

3. For Slip Fitted Assemblies, apply adhesive around the

leading edge of the pin and the inside of the collar and

use a rotating motion during assembly to ensure good

coverage.

4. For Press Fitted Assemblies, apply adhesive thoroughly

to both bond surfaces and assemble at high press on

rates.

5. For Shrink Fitted Assemblies the adhesive should be

coated onto the pin, the collar should then be heated to

create sufficient clearance for free assembly.

6. Parts should not be disturbed until sufficient handling

strength is achieved.

For Disassembly

1. Apply localized heat to the assembly to approximately

250 °C. Disassemble while hot.

For Cleanup

1. Cured product can be removed with a combination of

soaking in a Loctite solvent and mechanical abrasion

such as a wire brush.

Loctite Material Specification

LMS

LMS dated August

-

23, 1999. Test reports for each batch are

available for the indicated properties. LMS test reports include

selected QC test parameters considered appropriate to

specifications for customer use. Additionally, comprehensive

controls are in place to assure product quality and

consistency. Special customer specification requirements may

be coordinated through Henkel Quality.

Long Term Storage

Store product in the unopened container in a dry location.

Storage information may be indicated on the product container

labeling.

Optimal Storage: 8 °C to 21 °C. Storage below 8 °C or

greater than 28 °C can adversely affect product properties.

Material removed from containers may be contaminated during

use. Do not return product to the original container. Henkel

cannot assume responsibility for product which has been

contaminated or stored under conditions other than those

previously indicated. If additional information is required,

please contact your local Technical Service Center or

Customer Service Representative.

Conversions

(°C x 1.8) + 32 = °F

kV/mm x 25.4 = V/mil

mm / 25.4 = inches

µm / 25.4 = mil

N x 0.225 = lb

N/mm x 5.71 = lb/in

N/mm² x 145 = psi

MPa x 145 = psi

N·m x 8.851 = lb·in

N·m x 0.738 = lb·ft

N·mm x 0.142 = oz·in

mPa·s = cP

Note

The data contained herein are furnished for information only

and are believed to be reliable. We cannot assume

responsibility for the results obtained by others over whose

methods we have no control. It is the user's responsibility to

determine suitability for the user's purpose of any production

methods mentioned herein and to adopt such precautions as

may be advisable for the protection of property and of persons

against any hazards that may be involved in the handling and

use thereof. In light of the foregoing, Henkel Corporation

specifically disclaims all warranties expressed or implied,

including warranties of merchantability or fitness for a

particular purpose, arising from sale or use of Henkel

Corporation’s products. Henkel Corporation specifically

disclaims any liability for consequential or incidental

damages of any kind, including lost profits. The discussion

herein of various processes or compositions is not to be

interpreted as representation that they are free from

domination of patents owned by others or as a license under

any Henkel Corporation patents that may cover such

processes or compositions. We recommend that each

prospective user test his proposed application before repetitive

use, using this data as a guide. This product may be covered

by one or more United States or foreign patents or patent

applications.

Trademark usage
Except as otherwise noted, all trademarks in this document
are trademarks of Henkel Corporation in the U.S. and
elsewhere.

®

denotes a trademark registered in the U.S.

Patent and Trademark Office.

Reference 1.3

Henkel Americas

+860.571.5100

Henkel Europe

+49.89.320800.1800

Henkel Asia Pacific

+86.21.2891.8863

For the most direct access to local sales and technical support visit: www.henkel.com/industrial

Documentation Provided By HMC Electronics

33 Springdale Ave. Canton, MA 02021

http://www.hmcelectronics.com

(800) 482-4440