beautypg.com

Operating instructions safety system ces-az-als – EUCHNER CES-AZ-ALS-xxx (Unicode) User Manual

Page 9

background image

Operating Instructions Safety System CES-AZ-ALS-...

9

Note the following points:

Ì

Actuator and read head must be easily accessible for inspection and replace-
ment.

Ì

The switching operation must only be triggered by the specific actuator desig-
nated for this purpose.

Ì

Actuator and read head must be fitted so that

Ì

the front faces are at the minimum switch-on distance 0.8 x S

ao

or closer

when the safety guard is closed (see section Operating distances). To avoid
entering the area of possible side lobes, a minimum distance is to be main-
tained in case of a side approach direction. See section Typical operating
distance
for the related actuator.

Ì

when the safety guard is open up to the distance S

ar

(assured switch-off dis-

tance), a hazard is excluded.

Ì

the actuator is positively mounted on the safety guard, e.g. by using the
safety screws included.

Ì

they cannot be removed or tampered with using simple means.

Ì

Pay attention to the maximum tightening torque for the read head or safety
switch and actuator mountings of 1 Nm. For read heads/actuators made of
PE-HD, the maximum tightening torque is only 0.5 Nm.