Correct use
The Coded Electronic Ssafety switch series CES are a type series of technical
safety devices for monitoring moveable separating safety guards.
In combination with a separating safety guard and the machine control, this safety
component prevents dangerous machine movements from occurring while the
safety guard is open. A stop command is triggered if the safety guard is opened
during the dangerous machine function.
Before safety switches are used, a risk assessment must be performed on the
machine in accordance with:
Ì
EN ISO 13849-1, Safety of machinery. Safety related parts of control systems.
General principles for design
Ì
EN ISO 14121-1, Safety of machinery. Risk assessment. Principles
Ì
IEC 62061, Safety of machinery. Functional safety of safety-related electrical,
electronic and programmable electronic control systems.
Correct use includes compliance with the relevant requirements for installation
and operation, in particular
Ì
EN ISO 13849-1, Safety of machinery. Safety related parts of control systems.
General principles for design
Ì
EN 1088, Safety of machinery. Interlocking devices associated with guards.
Principles for design and selection
Ì
EN 60204-1, Safety of machinery. Electrical equipment of machines. General
requirements
Ì
EN 60947-5-3 Specification for low-voltage switchgear and controlgear. Con-
trol circuit devices and switching elements. Requirements for proximity devices
with defined behavior under fault conditions (PDF)
The following components can be connected to the evaluation unit CES-AZ--ALS... :
Ì
CES read heads
Ì
CEM read heads
Ì
CET read heads
Ì
CKS Electronic-Key adapter
For further information, refer to the operating instructions of the corresponding
component and to the following table Possible combinations for CES components.
Important:
Ì
The devices permit a safety-related stop function, initiated by a safety guard
according to Table 8 - DIN EN ISO 13849-1: 2008-12.
Ì
The safety-related function of the PDF is the opening of the output
contacts (13/14, 23/24) when the actuator is absent.
Ì
The user is responsible for the integration of the device into a safe overall
system. For this purpose, the overall system must be validated, e.g. in ac-
cordance with EN ISO 13849-2.
Ì
Correct use requires observing the permissible operating parameters (see
Technical data).
Ì
If a product data sheet is included with the product, the information on the
data sheet applies in case of discrepancies with the operating instructions.
Ì
It is only allowed to use components that are permissible in accordance with