Operating instructions safety system ces-az-als, Technical data ces-az-als-02b – EUCHNER CES-AZ-ALS-xxx (Unicode) User Manual
Page 22

Operating Instructions Safety System CES-AZ-ALS-...
22
Technical data CES-AZ-ALS-02B
Note:
If a product data sheet is included with the product, the information on the data
sheet applies in case of discrepancies with the operating instructions.
Parameter
Value
Unit
min.
typ.
max.
Housing material
Plastic PA6.6
Dimensions
114 x 99 x 45
mm
Weight
0.25
kg
Ambient temperature at U
B
= DC 24 V
-20
-
+55
°C
Atmospheric humidity, not condensing
-
-
80
%
Degree of protection
IP20
Degree of contamination
2
Mounting
DIN rail 35 mm according to EN 60715
Number of read heads
Max. 2 read heads per evaluation unit
Connection (screw terminals)
0.14
-
2.5
mm²
Operating voltage U
B
(regulated, residual ripple < 5 %)
21
24
27
V DC
Current consumption I
B
(with relay energized)
1)
-
150
-
mA
External fuse (operating voltage U
B
)
0.4
-
8
A
Safety contacts
2 (relays with internally monitored contacts)
Switching current (relay outputs)
mA
- At switching voltage AC/DC
21 ... 60 V
1
-
300
- At switching voltage AC/DC
5 ... 30 V
10
-
6000
- At switching voltage AC
5 ... 230 V
10
-
2000
External fuse (safety circuit) according to EN 60269-1
6 A gG or 6 A circuit breaker (characteristic B or C)
Utilization category according to EN 60947-5-1
AC-12 60V 0.3A / DC-12 60V 0.3A
AC-12 30V 6A / DC-12 30V 6A
AC-15 230V 2A / DC-13 24V 3A
Classification acc. to EN 60947-5-3
PDF-M
Rated insulation voltage U
i
250
V
Rated impulse withstand voltage U
imp
4
kV
Rated conditional short-circuit current
100
A
Resilience to vibration
In acc. with EN 60947-5-2
Mechanical operating cycles (relays)
10 x 10
6
Switching delay from state change
2)
- 2 activated actuators
-
-
290
ms
- 1 activated actuator
-
-
210
Time difference between the switching points of the two relays
-
-
25
ms
Manual start operating mode
- Duration of operation of start button
250
-
-
ms
- Start button response delay
-
200
300
Current via feedback loop Y1/Y2
5
8
10
mA
Permissible resistance via feedback loop
-
-
600
Ω
Ready delay
3)
-
10
12
s
Dwell time
4)
3
-
-
s
Switching frequency max.
5)
-
-
0.25
Hz
Repeat accuracy R acc. to EN IEC 60947-5-3
≤10
%
Monitoring outputs (diagnostics DIA, O1...O2, semiconductor
output, n-switching, short-circuit proof)
- Output voltage switched (low)
0
-
1
V DC
- Switching voltage
21
24
27
- Switching current
-
-
20
mA
Start button input S, test input TST
- Input voltage LOW
0
-
2
V DC
HIGH
15
-
U
B
- Input current
HIGH
5
8
10
mA
EMC protection requirements
According to EN60947-5-3
Reliability values according to EN ISO 13849-1
as a function of the switching current at 24 V DC
≤ 0.1 A
≤ 1 A
≤ 3 A
Category
4
Performance Level (PL)
e
PFH
d
1.9 x 10
-8
Mission time
20
years
Number of switching cycles/year
760 000
153 000
34 600
1) Without taking into account the load currents on the monitoring outputs.
2) Corresponds to the risk time according to EN 60947-5-3. This is the maximum switch-off delay for the safety outputs following removal of the actuator. In case of EMC interference in excess of
the requirements in accordance with EN 60947-5-3, the switch-off delay can increase to max. 430 ms. After a brief actuation < 0.4 s, the switch-on delay can increase to max. 3 s if this is fol-
lowed immediately by further actuation.
3) After the operating voltage is switched on, the relay outputs are switched off and the monitoring outputs are set HIGH during the ready delay. For the visual indication of the delay, the green
STATE LED flashes at a frequency of approx. 15 Hz.
4) The dwell time is the time that the actuator must be inside or outside the operating distance.
5) In case of monitoring with feedback loop, the actuators must remain outside the operating distance, e.g. with a door open, until the feedback circuit is closed.