beautypg.com

Environmental express, inc – Environmental Express SPE-Express with Cover User Manual

Page 9

background image

Environmental  Express,  Inc.

 

 

         800.343.5319/843.881.6560

 

 

8  

2.0 Getting Started

2.1 Unpacking Your Unit

When unpacking your unit, remove the rubber plug from the filter adapter. Care should be taken not to allow
particulate matter to get into the filter adapter or it may cause damage to the station valves. Save the rubber
plug to be used in long periods of non-use. Always lift the SPE-Express from the bottom, with one person on
each side of the unit. Avoid lifting from the front of the unit.

2.2 Setting Up the Hardware

Please read the system requirements and electrical requirements on page 7 of the manual.

2.2.1

Electrical Connections

Secure the following connections:

SPE-Express Power Cord to Power Source

USB Port to PC

Serial Cable to Bottle Rack (if equipped with Smart Bottle Rack)


SPE-XPress Getting Started

Setting Up Your Hardware

Environmental Express • 7

800.745.8218 / 843.576.1147 / www.environmentalexpress.com

Nitrogen - from Source

Nitrogen - to Reagents

Hexane
Deionized Water
Methanol

Vacuum Source

Water Miscible Waste

Hexane Waste

Power Indicator Light

Power Switch

Serial Cable to Bottle Rack

USB Port

to PC

Serial Cable to Additional SPE-XPress Unit

Fan

Power Cord

Exhaust
Duct

2.2.b Reagent Tubing Kit

Your SPE-XPress comes with a

Reagent Tubing Kit. Securely connect
each tubing line to the appropriate
port (see detail diagram, Figure 4).
- Hexane
- Deionized Water
- Methanol
- Vacuum
- Water Miscible Waste
- Hexane Waste

2.2 Setting Up Your Hardware

Before installation, carefully read

the system requirements and
electrical requirements on pages

?-?

of this manual.

2.2.a Connections
Secure the following connections:
- SPE-XPress Power Cord
- USB Port to PC
- Serial Cable to Bottle Rack if

applicable

- Serial Cable to additional

SPE-XPress if applicable

2.2.c Nitrogen Ports

Ports are provided to control your

Nitrogen flow.
- Nitrogen from Source
- Nitrogen to Reagents

2.2.d Exhaust Duct

- Do we want to say how to properly
vent the system?

Hexane

Deionized Water

Methanol

Vacuum Source

Water Miscible Waste

Hexane Waste

Close Up, Reagent Tubing
Kit Connections

Figure 3

Figure 4

Figure 2

Nitrogen - from source

Nitrogen - to reagents

Hexane

Deionized Water

Methanol

Exhaust Fan

Power Cord

Serial Cable to Additional
SPE-XPress Unit

Power Indicator Light

Serial Cable to
Bottle Rack

USB Port
to PC

Vacuum Source

Water Miscible Waste

Hexane Waste

Vent Fan

Air Intake for
Exhausting
Unit

Power Switch

Figure 3