Gold Trombone Installation Guide (EtherCAT and CAN)
Product Description
MAN-G-TROIG-EC (Ver. 1.604)
16
2.2.7.
Communications
•
Fast and efficient EtherCAT and CAN networking
•
EtherCAT Slave per part number:
CoE (CAN over EtherCAT)
EoE (Ethernet over EtherCAT)
FoE (File over EtherCAT) for firmware download
Supports Distributed Clock
EtherCAT cyclic modes supported down to a cycle time of 250 μs
•
CAN (DS-301, DS-305, DS-402) per part number. Refer to the section 4.11 for further details
•
Ethernet TCP/IP
UDP
Telnet
•
USB 2.0
2.2.8.
Safety
•
Approved IEC /EN 61800-5-1, Safety
•
Approved IEC/EN 61800-3, EMC
•
IEC 61800-5-2, Safe Torque Off (STO) with two STO inputs PLC level which can be
configured to 5 V logic (available on request)
•
UL 508C recognition
•
UL 60950 compliance
•
CE EMC compliance
2.2.9.
Digital Outputs
•
Four separate programmable high voltage digital outputs related to VDD and VDDRET:
TTL level: optically isolated sink and source
PLC: optically isolated source
Conforms to IEC 61131-2
Up to 30 VDC
High side logic (Source)
For S, 0 suffix, Digital Outputs 2,3,4 up to 250 mA
For T, 1 suffix, Digital Outputs 2,3,4 up to 7 mA
For S, 0 suffix, Digital Output 1 brake output: 500 mA
For T, 1 suffix, Digital Output 1: 7 mA
Short circuit protection
Thermal protection
Reverse polarity protection
•
The four outputs can be configured to 5 V Logic (available on request)