Feedback sensor specifications – ElmoMC Gold Line Digital Servo Drives-Gold Trombone User Manual
Page 15

Gold Trombone Installation Guide (EtherCAT and CAN)
Product Description
MAN-G-TROIG-EC (Ver. 1.604)
15
2.2.6.
Feedback Sensor Specifications
•
Incremental Encoder – up to 75 Megacounts per second (18 MHz PPS(Pulses Per Second))
•
Digital Halls:
Up to 4 kHz commutation frequency
5 V logic
Input voltage up to 15 VDC
•
Incremental encoder with digital Halls for commutation – up to 75 Megacounts per second
for encoder
•
Interpolated Analog (Sine/Cosine) Encoder:
Supports 1 V PTP Sin/Cos
Sin/Cos frequency: up to 500 kHz
Internal interpolation: up to ×8192
Automatic correction of amplitude mismatch, phase mismatch, signal offset
Emulated encoder output of the analog encoder
•
Analog Hall Sensor:
One feedback electrical cycle = one electrical cycle of the motor
Supports 1 V PTP Sin/Cos
Sin/Cos Frequency: up to 500 kHz
Internal Interpolation: up to ×8192
Automatic correction of amplitude mismatch, phase mismatch, signal offset
•
Resolver
14 bit resolution
Up to 512 revolutions per second (RPS)
Emulated encoder outputs of the resolver
•
Auxiliary encoder inputs (ECAM, follower, etc.) single-ended, unbuffered
•
Tachometer & Potentiometer
•
Absolute serial encoders:
NRZ (Panasonic, Tamagawa, Mitutoyo, etc.)
EnDAT 2.2
BiSS/SSI
The Gold Trombone can provide power (5 V, 2x200 mA max) for encoders, resolver or Halls.