Calibration
Turn on the scale and press/hold the tare key for 4 sec then
Let go and it will display F1, with the “Print” button go to F10 Cal
Press
“Tare “ to enter ,show “P----”; the initial pass ward is 1234 .
(
“Alarm” for next parameter; ”Print” for last parameter )
Press
“Tare “ to enter to
“P1 Cap” (capacity : 3kg,5kg,6kg,10kg,15kg,20kg,30kg)
“”P2 Inc” (1,2)
“P3 Zero track ” (off, 0.25, 0.5, 1, 1.5 , 2.0)
“P4 Auto zero” (off,1,2,4,5,10,20)”
“P5 key zero” (off,1,2,4,5,10,20)”
“P6 Filter” (1,2,3,4)
“P7 G1” gravity
“P8 G2” gravity
“P9 User Cal” user calibration, Press “tare” to enter
“Cal unit “ : choose kg, lb as calibration unit
Press
“tare” to enter, it show “unload”. Clear platform ,press”Tare”
Show
“000000”, enter weight value with numeric keys. Add weight
Press “tare” to show “Ld1 ” ; when “stab” on, press “Tare ”to succeed
calibration
“P9 linear Cal” Press “tare” to enter “Cal unit “ :
choose kg, lb as calibration unit
Press
“tare” to enter, it show “unload”. Clear platform , press ”Tare”
Show
“000000”, enter weight value with numeric keys. Add weight
Press “tare” to show “Ld1 ” ;
when
“stab” on, enter, it show “unload”. Clear platform , press ”Tare”
Show
“000000”, enter weight value with numeric keys. Add weight
Press “tare” to show “Ld2” ;
“P11 Pin” pass ward setting ; press” tare ” to show “P1----’;
Enter pass ward with numeric keys
Press
“tare” to show “P2----’
Enter pass ward again with numeric keys
Press
“Tare” to done the linear calibration
“P12 tare cont” ,press “tare” to enter “mode 1” or “mode 2”
“P13 Cal count”, press “tare to choose “pin” or “Jumper” way to enter
calibration mode