d. To enter new unit piece weight, repeat step b above.
6.5.2 Sampling Process
This method is used where unit piece weight is unknown or the weight of
individual piece is not highly standardized.
a. Refer to 6.2 and 6.4 for zero, selecting preferred weight unit and tare
operation,
b. Place a sample size with known quantity on platter
c. Enter the quantity of the sample through the numeric keypad and
confirm by pressing [# SET].
d. The instrument will automatically determine the unit piece weight and
display it on the Unit Piece Weight Panel
5
.
e. Step by step add more load onto the platter (or remove part of the
load from the platter),
f.
The latest Weight, unit piece weight and total quantity would be
displayed on the corresponding panels,
g. To start a new sampling, repeated step a to d above.
6.6 ABOUT AUTO PIECE WEIGHT ENHANCEMENT FUNCTION
In order to obtain the best counting result accuracy, the instrument is
equipped with Auto Unit Piece Weight Enhancement Function. This
function will automatically come into effect when an unit piece weight is
obtained through the sampling method as described in 6.5.2.
6.6.1 How Auto Unit Piece Weight Enhancement Function Works
After a unit piece weight is obtained by methods as described in 6.5.2, then
place more loads onto the platter. The new quantity will be shown on the
Total Count Panel. And at the same time, Auto Unit Piece Weight
Enhancement Function will update the unit piece weight if both below
requirements are fulfilled: -
a. The quantity added to platter is more than 1 piece, and
5
At this point, sampling process is completed and Auto Piece Weight
Enhancement Function comes into effect.