b. The quantity added to platter is less than 100% of the maximum

counts previously attained from the same transaction.

If the above requirements are fulfilled, a new unit piece weight will be

determined and displayed on the Unit Piece Weight Panel and confirmed

by 2 audio beeps.

Auto Unit Piece Weight Enhancement Function will terminate when: -

a. a zero weight is detected or during the transaction process, or

b. quantity added is more than 100% of the maximum counts previously

attained from the same transaction, or

c. quantity removed is not more than 50% of the maximum counts

previously attained from the same transaction.

To start Auto Piece Weight Enhancement Function again after

terminated, repeat 6.5.2.

6.7 MEMORY ACCUMULATION FUNCTION
6.7.1 To Accumulate a Transaction to Memory

6

7

8

a. When quantity is being displayed on Quantity Panel, press [M+]

9

to

and accumulate data of current transaction to memory,

b. The instrument: -

displays “ACC” on Weight Panel. ACC denotes data has been
accumulated to memory,

displays “n” on Unit Piece Weight Panel. n donates the number
of transactions which have been accumulated to memory.

displays Total Indicator and total accumulated value on

Quantity Panel.

6

Transaction with zero quantity will not be accumulated.

7

Transaction with weight less than 20d will not be accumulated.

8

All data stored will be erased when the instrument is powered off or changing

weight unit.

9

Unstable weight will not be accumulated to memory. If M+ is pressed when weight

is unstable, the instrument will reject this command and response with 2 beeps.