Capacities, Power – Despatch LCC1-51-3 User Manual
Page 13

4
Capacities
Model
LCC/D1-16-3
LCC/D1-16N-3
LCC/D1-51-3
LCC/D1-51N-3
Maximum
Load (Lbs)
200
200
200
200
Maximum Shelf
Load (Lbs)
50
50
25
25
Recirculating
Fan
CFM
H.P.
240
1/4
240
1/4
435
1/4
435
1/4
Net Lbs
Weight (KG)
(Approximate)
250
(114)
250
(114)
380
(172)
380
(172)
Shipping Lbs
Weight (KG)
(Approximate)
350
(159)
350
(159)
525
(238)
525
(238)
Exhaust
Capacity
(CFM)
(forced exhaust)
35
35
73
73
Exhaust Outlet
inches
(mm)
1.88 x 2.88
(48.0 x 73.4)
1.88 x 2.88
(48.0 x 73.4)
1.88 x 2.88
(48.0 x 73.4)
1.88 x 2.88
(48.0 x 73.4)
Power
If your line voltage is much lower than the oven voltage rating, heat up time is
significantly longer and motors may overload or run hot. If your line voltage is higher
than the nameplate rating, the motors may run hot and draw excessive amps. If the line
voltage varies more than 10% from the oven voltage rating, some electrical components
such as relays, temperature controls, etc. may operate erratically.
Model
Volts *
Amps
Hertz
Heater Phase
KW
Cord and Plug
LCC/D1-16-3
240
14.8
50/60
1
3
None, hardwired
LCC/D1-16N-3
240
14.0
50/60
1
3
None, hardwired
LCC/D1-51-3
240
27.7
50/60
1
6
None, hardwired
LCC/D1-51N-3
240
27.7
50/60
1
6
None, hardwired
*Oven designed for 240 volts (see nameplate on oven) will operate satisfactorily on a
minimum of 208 Volts, but will result in 25% reduced heater output. If your power
characteristic is lower, contact Despatch Industries.