CHAMPION DH5000 VHR Manual User Manual
Page 18

10
Water Connections for Standard Model and Direct Vent Option Model
The incoming hot water line is a 3/4" NPT connection.
! ATTENTION !
A qualified plumber must connect the water supply to the dishwasher in accordance with all
local plumbing and sanitation codes and regulations.
Improper installation will not be covered by the Limited Warranty.
Installation
1. The DH5000 Standard Model dishwasher and the DH5000 Direct Vent Option Model
require a single hot water connection
HOT WATER — 3/4" NPT, 110°F/43°C minimum temperature, with a minimum incoming
flowing pressure of 45 PSI measured at the dishwasher before adjusting operating
pressure to 20/25 PSI flowing pressure.
2. A water hardness of 3 grains/gal (US) [51.3 mg/L] or less is recommended.
3. A manual shut-off valve, 3/4" or larger, should be installed in the hot water supply line
as close to the dishwasher as possible for servicing.