It2000-ab, Troubleshooting, 17 of 38 – BAND-IT IT2000-AB 1/4 Junior Tool User Manual
Page 17: 1/4” junior, Tool

Document # I17792 Rev G
© Copyright
BAND-IT-IDEX, Inc. 2009
All rights reserved
www.BAND-IT-IDEX.com
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street Denver, CO 80216-0307 USA
P: 1-800-525-0758 F: 1-800-624-3925
17 of 38
IT2000-AB
1/4” Junior
®
Tool
Tool Fails to Cut Off Clamp Tail:
• The Inlet Air Pressure may be low. Check air supply to Air Controller Module. Cut-off
Pressure Gauge should indicate 100 -110 PSI (690-760 kPa). See pages 4 - 6 for air supply
requirements.
• The scrap clamp tail from the previous clamp may not have been removed. Press the Reset
Button to release the tension on the clamp and remove the scrap clamp tail.
• The Cutter Blade or Knife may be worn. See below for Cutter Blade inspection and
replacement.
• Note: The Flip Cover Tightening Screw and Flip Cover Head Screws are factory tensioned
and will need to have thread locking compound re-applied and be re-tensioned after the
quick release pins are re-installed upon completion of maintenance.
2. Remove Flip
Cover and
Tension Block
Assembly for
cleaning and
lubrication.
3. Remove the Cutter
Blade Pin and Cutter
Blade. The Cutter Blade
has two working edges
and can be rotated 180
°
to use the second edge
prior to replacement.
4. When installing
the Cutter Blade
Pin, use a small
screwdriver to
push the front
gripper toward the
back of the tool.
1. Loosen the Flip Cover
Tightening Screw and
Flip Cover Head Screws
(see note above) to
remove both Quick
Release Pins as shown.
Cutter Blade inspection and replacement:
Front
Gripper
Cutter
Blade Pin
Troubleshooting