Device restart, Factory reset – 2N Helios IP Verso User Manual
Page 85
![background image](/manuals/553602/85/background.png)
85
Legend
LAN
(PoE)
LAN (PoE according to 802.1af) connector
IN1
IN1 terminals for input in passive/ active mode (−30 V to +30 V DC)
OFF = open OR U
> 1.5 V
IN
ON = closed contact OR U
< 1.5 V
IN
OUT1
OUT1 terminals of active input for
or
2N Helios IP Security Relay
®
electric lock connection 8 up to 12 V DC depending on power supply (PoE:
10 V; adaptor: power supply voltage minus 2 V), max 400 mA
RELAY1 RELAY1 terminals with accessible 30 V / 2 A AC/DC NO/NC contact
12V/2A External 12 V / 2 A DC supply terminals
GND
Grounding terminal
RESET
RESET / FACTORY RESET button
RGY
LED indicators (red/green/yellow)
LINE
OUT
LINE OUT connector (1 V
)
RMS
MIC
MIC connector for microphone connection
BUS
2N
®
Helios IP Verso bus connector
Device Restart
Press the RESET button shortly to restart the device.
Factory Reset
2N
®
Helios IP Verso is equipped with a RESET button. Press the button shortly (< 1
s) to restart the system without changing configuration.
Follow the instructions below to
:
identify the current IP address
Press and hold the RESET button.
Wait until the red and green LEDs on the device come on simultaneously (approx.
20 s).
Release the RESET button.
The device announces the current IP address via the loudspeaker connected
automatically.
Follow the instructions below to switch on the
mode (DHCP OFF):
Static IP address
Press and hold the REST button.
Wait until the red and green LEDs on the device come on simultaneously (approx.
20 s).
Wait until the red LED goes off (approx. 5 s).
Release the RESET button.
The following network parameters will be set after restart:
IP address: 192.168.1.100