beautypg.com

Setcamerainput, Controlrtpstream, Action.setcamerainput – 2N Helios IP Automation Manual v2.8 User Manual

Page 26: Action.controlrtpstream, Parameters, Example

background image

26

2N TELEKOMUNIKACE a.s., www.2n.cz

®

Action.SetCameraInput

The

block defines the action that switches the video signal sources –

SetCameraInput

either the integrated video camera or an external IP camera, or two inputs for
analogue camera connection to the

.

2N Helios IP Video Kit

®

Parameters

Event – define the event to launch this action.
Condition – define the condition to be met for the action to be executed. This
parameter is optional.
Type – define the video signal type. A change during a call will apply only for this
call. Other video receivers receive video from the same source

.

Valid values:

internal – internal camera (or external analogue video camera
connected directly to the device)

external – external IP camera.

The parameter is optional, the default value is

.

internal

Id – define the video signal channel. The parameter is available with the 2N

®

Helios IP Video Kit model only and applicable only if the Type parameter is set to

.

internal

Valid values:

1 – analogue camera connected to input 1
2 – analogue camera connected to input 2

The parameter is optional, the default value is .

1

Example

Switch the video signal source to the first external analogue camera input if the event
defined on row 2 arises:

Action.SetCameraInput: Type=internal; Id=1; Event=2

Action.ControlRtpStream

Block

defines the action that controls the flow of the RTP streams.

ControlRtpStream

This action controls only call streams; multicast streams are not affected by this action.