Parameters
Code – define the numeric code.
Valid values:
numeric code – 12345, e.g.
SuppressTones – suppress sound signalling initiated by receiving of an invalid
numeric code. The parameter is optional.
Valid values:
0 – tones are not suppressed
1 – tones are suppressed (default value).
Variables
Code – the received numeric code which was the last to generate this event.
Example
Event generated by entering code 12345* on a keypad:
Event.CodeEntered: Code=12345
Event.CardEntered
The
block defines the event generated by tapping (swiping) of the RFID
CardEntered
card with the defined ID (for RFID card reader models only).
Parameters
Card – define the RFID card ID; refer to the Card Reader subsection in the 2N
®
.
Helios IP Configuration Manual
Valid values:
valid – any valid card (included in the intercom card list)
invalid – any invalid card
any - any valid or invalid card
card ID - defined card ID e.g. 3F00F34F78.
SuppressTones – suppress sound signalling initiated by detection of an invalid
card. The parameter is optional.
Valid values:
0 – tones are not suppressed
1 – tones are suppressed (default value).
Variables
Card – ID of the detected card which was the last to generate this event.