Section 4 - operation, 1 engine, Starting the engine – JLG G10-43A (0160005444 & After) Operator Manual User Manual
Page 69: 1 engine -1, Starting the engine -1, Warning

Section 4 - Operation
4-1
31200150
SECTION 4 - OPERATION
4.1
ENGINE
Starting the Engine
This machine can be operated under normal conditions in temperatures of 0°F to
104°F (-20°C to 40°C). Consult JLG for operation outside this range or under
abnormal conditions.
If equipped for extreme cold weather, -40°F to 0°F (-40°C to -20°C), see page 4-3
for starting procedure.
1. Make sure all controls are in “Neutral” and all electrical components (lights,
heater, defroster, etc.) are turned off. Set parking brake.
2. (Before S/N 0160040675 excluding 0160040468 & 0160040672) If equipped
with Perkins engine and the temperature is below 32° F (0° C), turn the ignition
switch to “RUN”. Depress and hold engine pre-heat switch for approximately 10
seconds.
(S/N 0160040675 & After including 0160040468 & 0160040672) Turn the
ignition switch to “RUN” position and wait until engine pre-heat indicator light
goes out.
3. Turn ignition switch to “START” to engage starting motor. Release key
immediately when engine starts. If engine fails to start within 20 seconds,
release key and allow starting motor to cool for a few minutes before trying
again.
4. After engine starts, observe oil pressure gauge. If gauge remains on zero for
more than ten seconds, stop engine and determine cause before restarting
engine. Reference engine manual for minimum pressure at operating
temperature.
5. Warm up engine at approximately 1/2 throttle.
Note: Engine will not start unless transmission control lever is in “Neutral” and park
brake switch is applied.
WARNING
UNEXPECTED MOVEMENT HAZARD. Always ensure that transmission control
lever is in neutral and the service brake is applied before releasing park brake.
Releasing park brake in either forward or reverse could cause the machine to
move abruptly, causing an accident.