JLG 1350SJP Service Manual User Manual
Page 483
SECTION 6 - JLG CONTROL SYSTEM
3121142
– JLG Lift –
6-107
9941
99
41
CHASSIS SENSOR SUPPLY OUT OF RANGE LOW
The Chassis Sensors supply volt-
age is low.
9942
99
42
BLAM BACKUP COMMUNICATIONS LINK FAULTY
The BLAM backup communica-
tions link test was activated at
startup, but no communication
connection established/main-
tained.
- BLAM equipped vehicles only.
-1250
9943
99
43
BLAM BACKUP COMMUNICATIONS LOST - HYDRAULICS SUSPENDED
The BLAM backup communica-
tions link was activated, but no
communication connection
established/maintained.
- BLAM equipped vehicles only.
-1250
9944
99
44
CURRENT FEEDBACK GAINS OUT OF RANGE
The factory set current feedback
gains are out of range.
9945
99
45
CURRENT FEEDBACK CALIBRATION CHECKSUM INCORRECT
The factory set current feedback
checksum is not correct.
9975
99
75
LOAD PIN NOT CALIBRATED
The Load Pin has not been cali-
brated.
-1250
9979
99
79
FUNCTIONS LOCKED OUT - GROUND MODULE SOFTWARE VERSION
IMPROPER
Temporary fault for the telemat-
ics project. The model needs to
be a 600S or 1350S if not this
fault will be generated and Plat-
form controls will be prevented.
This fault was to insure that the
software will only work for
these two models.
Table 6-6. Diagnostic Trouble Code Chart
DTC
Flash
Code
Sequence
Fault Message
Fault Description
Check