JLG 1350SJP Service Manual User Manual
Page 395
SECTION 6 - JLG CONTROL SYSTEM
3121142
– JLG Lift –
6-19
GEN SET/WELDER:
10
0
1
2
NO: No generator installed.
BELT DRIVE: Belt driven setup.
HYDRAULIC DRIVE: Hydraulic driven setup.
1
GEN SET CUTOUT:
11*
0
1
MOTION ENABLED: Motion enabled when generator is ON.
MOTION CUTOUT: Motion cutout in platform mode only.
0
* Only visible if Gen Set / Welder Menu selection is not 0.
H & T LIGHTS:
12
0
1
NO: No head and tail lights installed.
YES: Head and tail lights installed.
0
LOAD SYSTEM:
13*
0
1
2
3
4
NO: No load sensor installed.
WARN ONLY: Functions in creep, overload lamp lit, platform alarm beeps (5 sec ON, 2 sec OFF).
CUTOUT PLATFORM: All functions cutout, overload lamp lit, platform alarm beeps (5 sec ON, 2 sec OFF).
CUTOUT ALL: All functions cutout, flash overload light (500mS on, 500mS off), platform alarm beeps (5
sec ON, 2 sec OFF).
SPECIAL 1: Functions in creep, overload lamp lit, disables main telescope out & main lift up, platform
alarm beeps (5 sec ON, 2 sec OFF).
0
* Only visible under certain market selections.
* Certain market selections will limit load system options or alter default setting.
Table 6-2. Machine Configuration Programming Information - Version P7.X to Present
Configuration Digit
Number
Description
Default
Number