JLG 1350SJP Service Manual User Manual
Page 419
SECTION 6 - JLG CONTROL SYSTEM
3121142
– JLG Lift –
6-43
ENVELOPE:
Displayed if MODEL NUMBER = 7 or 8
LENGTH
XXXX.X
Displays the current indicated boom length in inches.
ANGLE 1
XX.X
Displays the current indicated boom angle 1 in degrees.
ANGLE 2
XX.X
Displays the current indicated boom angle 2 in degrees.
A/D LNGTH
XXXXX
Displays the current indicated boom length in A/D counts.
A/D ANG1
XXXXX
Displays the current indicated boom angle 1 in A/D counts or raw angle if cali-
brated.
A/D ANG2
XXXXX
Displays the current indicated boom angle 2 in A/D counts or raw angel if cali-
brated.
CAN STATISTICS:
CAN Statistics as detected by the Ground Module
RX/SEC
XXX
Displays the number of received messages per second
TX/SEC
XXX
Displays the number of transmitted messages per second
BUS OFF
XX
Displays the number of bus off occurrences
PASSIVE
XX
Displays the number of bus passive occurrences
Table 6-5. Machine Diagnostics Parameters
Diagnostics Submenu
(Displayed on Analyzer
1
st
Line)
Parameter (Displayed on
Analyzer 2
nd
Line)
Parameter Value
(Displayed on Analyzer 2
nd
Line)
Description