JLG 1350SJP Service Manual User Manual
Page 460
SECTION 6 - JLG CONTROL SYSTEM
6-84
– JLG Lift –
3121142
236
23
6
FUNCTION SWITCHES LOCKED - SELECTED BEFORE START SWITCH
A boom function was selected
before engine start.
237
23
7
START SWITCH LOCKED - SELECTED BEFORE KEYSWITCH
The Start Switch was closed dur-
ing power-up.
250
25
0
<<< FUNCTION PREVENTED >>>
259
25
9
MODEL CHANGED - HYDRAULICS SUSPENDED - CYCLE EMS
The model selection has been
changed.
2513
25
13
GENERATOR MOTION CUTOUT ACTIVE
Driving is not possible while the
vehicle generator is running
AND is configured to prevent
drive.
2514
25
14
BOOM PREVENTED - DRIVE SELECTED
Boom functions are not possible
while the vehicle is being driven
AND is configured to not allow
simultaneous drive & boom
operation.
2515
25
15
DRIVE PREVENTED - BOOM SELECTED
Driving is not possible while the
vehicle above elevation AND is
configured to prevent drive
while above elevation.
2516
25
16
DRIVE PREVENTED - ABOVE ELEVATION
Driving is not possible while
Boom functions are selected
AND is configured to not allow
simultaneous drive & boom
operation.
2517
25
17
DRIVE PREVENTED - TILTED & ABOVE ELEVATION
Driving is not possible while the
vehicle is tilted and above eleva-
tion AND is configured to pre-
vent drive while tilted and
above elevation.
2521
25
21
JIB SWING PREVENTED - IN 1000# MODE
JIB Swing is not possible while
the vehicle is in 1000 LB Mode.
2522
25
22
CAN DONGLE ATTACHED - HYDRAULICS NOT RESTRICTED
CAN Dongle attached. Very lim-
ited restrictions for all hydrau-
lics systems.
2523
25
23
BACKUP BLAM COMMUNICATIONS ACTIVE
RS232 serial backup communi-
cations link to the BLAM is
active.
2524
25
24
DISCONNECT ANALYZER AND CYCLE EMS TO PERFORM BOOM RETRIEVAL
RS232 serial backup communi-
cations link to the BLAM is
needed but an analyzer is con-
nected.
Table 6-6. Diagnostic Trouble Code Chart
DTC
Flash
Code
Sequence
Fault Message
Fault Description
Check