9 machine personality settings/function speeds, Machine personality settings/function speeds -23, Personality ranges/defaults -23 – JLG 1350SJP Service Manual User Manual
Page 399
SECTION 6 - JLG CONTROL SYSTEM
3121142
– JLG Lift –
6-23
6.9
MACHINE PERSONALITY SETTINGS/FUNCTION
SPEEDS
NOTE:
Personality settings can be adjusted within the adjustment
range in order to achieve optimum machine performance.
Table 6-3. Personality Ranges/Defaults
SUBMENU
(DISPLAYED ON
ANALYZER 1ST LINE)
PARAMETER
(DISPLAYED ON ANALYZER 2
ND
LINE)
DESCRIPTION
RANGE
DEFAULT VALUES
TIME RANGE (SEC) (SEE
SECTION 6.10 FOR
MACHINE ORIENTATION
WHEN SETTING SPEEDS)
1200
1350
1200S
1350S
DRIVE:
ACCEL X.Xs
Displays/adjusts drive acceleration
0.1 to 5.0 sec
2.0
2.0
DECEL X.Xs
Displays/adjusts drive deceleration
0.1 to 3.0 sec
1.3
1.3
MIN forward XX%
Displays/adjusts minimum forward drive
speed
0 to 35%
1
1
MAX forward XXX%
Displays/adjusts maximum forward drive
speed
0 to 100%
100
100
44-48
44-48
MIN reverse XX%
Displays/adjusts minimum reverse drive speed 0 to 35%
1
1
MAX reverse XXX%
Displays/adjusts maximum reverse drive speed 0 to 100%
100
100
44-48
44-48
ELEV. MAX XX%
Displays/adjusts maximum drive speed
NOTE: used when elevation cutout switches are
limiting maximum speed
0 to 50%
25
25
93-104
93-104
CREEP MAX XX%
Displays/adjusts maximum drive speed
NOTE: used when creep switch on pump pot is
active
0 to 50%
35
35
79-87
79-87
STEER:
max SPEED XXX%
Displays/adjusts maximum steer speed.
0 to 100%
100
100
MAIN LIFT:
ACCEL X.Xs
Displays/adjusts main lift acceleration
0.1 to 5.0 sec
1.0
1.0
DECEL X.Xs
Displays/adjusts main lift deceleration
0.1 to 3.0 sec
1.0
1.0
MIN Up XX%
Displays/adjusts minimum main lift up speed
0 to 60%
20
20
MAX UP XX%
Displays/adjusts maximum main lift up speed
0 to 100%
50
50
75-100
75-100
MIN DOWN XX%
Displays/adjusts minimum main lift down
speed
0 to 60%
10
10
MAX DOWN XXX%
Displays/adjusts maximum main lift down
speed
0 to 100%
50
50
85-110
85-110
CREEP UP XX%
Displays/adjusts maximum main lift up speed
NOTE: used when creep switch on pump pot is
active
0 to 65%
50
50
CREEP DOWN XX%
Displays/adjusts maximum main lift down
speed
NOTE: used when creep switch on pump pot is
active
0 to 75%
45
45