JLG 1350SJP Service Manual User Manual
Page 402
SECTION 6 - JLG CONTROL SYSTEM
6-26
– JLG Lift –
3121142
GROUND
MODE:
U. LIFT UP XXX%
Displays/adjusts fixed main lift up speed
0 to 100%
60
60
U. LIFT DN XXX%
Displays/adjusts main lift down speed
0 to 100%
60
60
SWING XXX%
Displays/adjusts fixed swing speed
0 to 100%
60
60
BASKET LVL XXX%
Displays/adjusts fixed basket level speed
0 to 100%
75
75
BASKET ROT XXX%
Displays/adjusts fixed basket rotate speed
0 to 100%
75
75
MAIN TELE XXX%
Displays/adjusts fixed main telescope speed
0 to 100%
60
60
TOWER TELE XXX%
Displays/adjusts fixed tower telescope speed
Not displayed if TOWER TELE=NO
0 to 100%
100
100
T. LIFT UP XXX%
Displays/adjusts fixed tower lift up speed
Not displayed if TOWER LIFT=NO
0 to 100%
100
100
T. LIFT DN XXX%
Displays/adjusts fixed tower lift down speed
Not displayed if TOWER LIFT=NO
0 to 100%
100
100
JIB (U/D) XXX%
Displays/adjusts jib lift speed
Not displayed if JIB = 0
0 to 100%
60
60
JIB (L/R) XXX%
Displays/adjusts jib swing speed
Displayed if JIB = 2
0 to 100%
70
70
GEN SET/WELDER:
ENGINE XXXX RPM
Control generator/welder RPM. Not displayed if
GEN SET/WELDER = 0
1200-2800
1800
1800
4150453-F
Table 6-3. Personality Ranges/Defaults
SUBMENU
(DISPLAYED ON
ANALYZER 1ST LINE)
PARAMETER
(DISPLAYED ON ANALYZER 2
ND
LINE)
DESCRIPTION
RANGE
DEFAULT VALUES
TIME RANGE (SEC) (SEE
SECTION 6.10 FOR
MACHINE ORIENTATION
WHEN SETTING SPEEDS)
1200
1350
1200S
1350S