JLG 1350SJP Service Manual User Manual
Page 393
SECTION 6 - JLG CONTROL SYSTEM
3121142
– JLG Lift –
6-17
Table 6-2. Machine Configuration Programming Information - Version P7.X to Present
Configuration Digit
Number
Description
Default
Number
NOTE:
The machine configuration must be completed before any personality settings can be changed. Changing the personal-
ity settings first and then changing the model number of the machine configuration will cause the personality settings
to return to default
MODEL NUMBER:
1
1
2
3
1200S
1250A
1350S
1
ENVELOPE HEIGHT:
2
1
2
3
4
5
6
7
8
9
1350S: 135' MAX
1350S: 125' MAX
1350S: 120' MAX
1350S: 110' MAX
1200S: 120' MAX
1200S: 110' MAX
1250A: 125' MAX
1250A: 100' MAX
1250A: 80' MAX
5
Note: The default settings (bold) will vary depending on the model selection with selection # 5 being the initial default setting.
MARKET:
3
0
1
2
3
4
5
ANSI USA
ANSI EXPORT
CSA
CE
AUSTRALIA
JAPAN
0
ENGINE:
4
1
2
3
DEUTZ F4 TIER1: Deutz BF4M1011 Diesel (Tier 1)
DEUTZ F4 TIER2: Deutz BF4M2011 Diesel (Tier 2)
DEUTZ ECM: Engine Control Module
3