SECTION 6 - TROUBLESHOOTING
3121231
– JLG Lift –
6-19
Code 02 - Left PHP Bar - UP
Check For These Obvious Conditions First:
• Obstruction under LEFT pot hole bar.
• Obstruction around the actuator assembly at the base of the mast.
Code 03 - Right PHP Bar - UP
Check For These Obvious Conditions First:
• Obstruction under RIGHT pot hole bar.
• Obstruction around the actuator assembly at the base of the mast.
Table 6-7. Code 02 - Left PHP Bar - UP
STEP
ACTION
SPEC
YES
NO
CHECK THE FOLLOWING WITH THE PLATFORM ELEVATED 3 TO 4 FEET (1 TO 1.5m)
1.
Go to the 20 pin molex connector at the Ground Control Module, back probe
to check for continuity of pin 10, (BLK #8 wire) with pin 20, (ORG/RED 49-
1 wire). Is there continuity?
—
Replace Ground
Control Module
Go to Step 2
2.
Check the actuator cables for adjustment or damage.
—
Adjust or Replace
Go to Step 3
3.
Check the PHP limit switch(s) at both sides of the machine for damage,
adjustment and for continuity through switch to ground when bars are
down.
—
Replace, Adjust or
Repair Wiring
—
Table 6-8. Code 03 - Right PHP Bar - UP
STEP
ACTION
SPEC
YES
NO
CHECK THE FOLLOWING WITH THE PLATFORM ELEVATED 3 TO 4 FEET (1 TO 1.5m)
1.
Go to the 20 pin molex connector at the Ground Control Module, back probe
to check for continuity of pin 9, (BLK #9 wire) with pin 19, (ORG/RED 49-2
wire). Is there continuity?
—
Replace Ground
Control Module
Go to Step 2
2.
Check the actuator cables for adjustment or damage.
—
Adjust or Replace
Go to Step 3
3.
Check the PHP limit switch(s) at both sides of the machine for damage,
adjustment and for continuity through switch to ground when bars are
down.
—
Replace, Adjust or
Repair Wiring
—