SECTION 5 - MAST COMPONENTS
5-30
– JLG Lift –
3121231
5.12 MAST - 14 FT. HEIGHT LIMITING
SWITCH -15MSP (OPTION)
Ground Control Module Programming settings required:
• Set Ancillary 2 POL to HIGH (Up Arrow)
Location of Proximity Switch and Target
(Right side of mast from rear)
1. Proximity Switch
2. Target Plate
Proximity Switch Installation
1. Mounting Screws, Nuts
and Washers
2. Switch Shim
3. Proximity Switch
4. Harness Connector (a)
NOTE: (a) Proximity switch wiring is routed through hole in
the mast connect support to main harness "Aux 2
Input" connector (orange/red 49-6, black 13),
located under center rear cover on the left side of
the pump/motor.
Target Plate Installation
1. Target Plate
2. Mounting Screws and
Washers (a)
NOTE: (a) Secure to mast using existing holes.