beautypg.com

Snorkel TB50 User Manual

Page 75

background image

Chapter 11 – Troubleshooting

TB42/TB50 – 0074923

71

Symptom

Possible Cause

Corrective Action

Engine starts from the upper con-

trols but no boom functions work

– machines with AC generator op-

tion only.

The AC generator switch is in the

generator position.

Place the switch in the machine posi-

tion to operate machine functions.

Engine dies when the control selector

switch at the lower controls is placed

in the upper control position.

Upper controls are not set-up prop-

erly.

At the upper controls, pull the emer-

gency stop button upward and turn

the anti-restart master switch on.

Constant tone alarm sounds while

the engine is running.

High engine temperature.

Lower the platform and turn the

engine off and let it cool. Do not

restart the engine until the cause of

overheating has been corrected.

Low oil pressure.

Lower the platform and turn the

engine off. Do not restart the engine

until the cause of low oil pressure

has been corrected.

No alternator current/broken fan

belt.

Turn the engine off. Do not restart

the engine until the cause of no al-

ternator current has been corrected

or the fan belt is replaced.

Constant tone alarm sounds and

engine shuts off.

High engine temperature.

Let the engine cool. Do not restart

the engine until the cause of over-

heating has been corrected.

Low oil pressure.

Do not restart the engine until the

cause of low oil pressure has been

corrected. The engine can be re-

started with low oil pressure, but it

will only run a few seconds before it

shuts off again.

All functions stop working.

Low fluid level in reservoir.

Check fluid level. Add correct type

of fluid if necessary.

Engine or pump failure.

Manually stow the machine using

the emergency power system or the

emergency lowering knob.

Circuit breaker is tripped.

Push circuit breaker button in to

reset.

Electrical system malfunction.

Manually lower the boom using the

emergency lowering knob.

Lower controls do not work.

Battery disconnect switch turned off.

Place switch in the on position.

Emergency stop switch at lower con-

trols is pushed in to the off position.

Pull the emergency stop button

outward.

Control selector switch is in the upper

control position.

Place the switch in the lower control

position.

Ground operation switch not held in

the on position.

Hold the ground operation switch in

the on position while operating the

control toggle switches.

Upper controls do not work.

Battery disconnect switch turned off.

Place switch in the on position.

Emergency stop button at lower and

upper controls is in the off position.

Pull the emergency stop buttons

outward.

Control selector switch at lower con-

trols is in the lower control position.

Place switch in the upper control

position.

Platform foot switch not engaged.

Step down on platform foot switch

while operating controls.