Chapter 3 – Safety

Knowledge of the information in this manual, and

proper training, provide a basis for safely operating the

aerial platform. Know the location of all controls and

how they operate to act quickly and responsibly in an

emergency.

Safety devices reduce the likelihood of an accident.

Never disable, modify, or ignore any safety device.

Safety alerts in this manual indicate situations where

accidents may occur.

If any malfunction, hazard or potentially unsafe condition

relating to capacity, intended use, or safe operation is sus-

pected, stop aerial platform operation and seek assistance.

The operator bears ultimate responsibility for following

all manufacturer’s instructions and warnings, regulations

and safety rules of their employer and/or any state or

federal law.

Electrocution Hazards

The aerial platform is made of metal components and is

not insulated. Regard all conductors as energized. Do

not operate outside during a thunderstorm.

Minimum Safe Approach Distance

Minimum safe approach distances to energized power

lines and their associated parts must be observed while

operating the aerial platform.

Danger

The aerial platform is not electrically insulated.

Death or serious injury will result from contact

with, or inadequate clearance from, an energized

conductor. Do not go closer than the minimum safe

approach distance as defined by ANSI.

ANSI publications define minimum distances that must

be observed when working near bus bars and energized

power lines. Table 1 and Figure 3 are reprinted courtesy

of Scaffold Industry Association, ANSI/SIA A92.5.

Table 1 – Minimum Safe Approach Distance

Figure 3 – Minimum Safe Approach Distance

Voltage Range

(Phase to Phase)

Minimum Safe Approach Distance

Feet

Meters

0 to 300V

Avoid Contact

Over 300V to 50kV

10

3.05

Over 50kV to 200kV

15

4.60

Over 200kV to 350Kv

20

6.10

Over 350kV to 500kV

25

7.62

Over 500kV to 750kV

35

10.67

Over 750kV to 1000kV

45

13.72

Denotes

prohibited

zone